Worth Data 802 RF Spécifications Page 41

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 119
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 40
6-4
promptline2 as string
promptline3 as string
NextIfError as integer
NextIfOK as integer
End Type
dim TransactionSequence(10) as TransactionElement
TransactionSequence(1).commandcode = 1 'InputAny
TransactionSequence(1).promptline1 = "Go to Location " +
GetLocationCode
TransactionSequence(1).promptline2 = "Press Enter When
Ready "
TransactionSequence(1).NextIfError = 1
TransactionSequence(1).NextIfOK = 2
Etc.
As mentioned above, it is important to keep your event handlers short and
efficient. This means that your program should spend as little time as
possible "inside" the event handler (running the handler's code). Also, it is
important to NOT call WD802Term methods from inside WD802Term
event handlers. So a solution is needed that allows your program to respond
to events outside of the event handlers.
An easy way to do this is with a polling scheme. Add a timer object to your
application and in the timer's event handler check the
TermData structure
for the state of each terminal and make any appropriate WD802Term
method calls from within the timer object's event handler. The timer can be
set to fire every 100 milliseconds or every 10 seconds or anything in
between that is appropriate for your application.
Another, more advanced way to decouple the WD802Term method calls
from the event handlers is using threading techniques where each terminal
is "running" in a thread that monitors that terminal's state.
WD802Term/ActiveX
WD802Term is a drop in ActiveX component that allows programmers to
easily add the ability to send prompts to and receive data from their R/F
Terminal across a wireless 802.11b Ethernet network connection.
The ActiveX component is compatible with Visual Basic, Visual C++,
Delphi, and most other 32-bit development platforms.
Programming Considerations
Remember, plan for every error that the Server might return including:
Sequence Errors detected
Illegal Command detected
Addressing a Terminal Not Signed In