Narda 37NBM-580
4.5Remotecommandsandinstructions
Commandabbreviations
Inthenextchapterallcommandsaredescribedinatable.
Somecolumnshaveaveryshortheaderwhichisnotself
explanatory.Thefollowingtabledescribestheseshort
headers:
S Belongs to a Setcommand
G Belongs to a Getcommand
R Belongs to the Response of a
getcommand
Inthenextchapter“Commands”thereisalsoinformation,
regardingparametersanddefaultvalues,included:The
factorydefaultsvaluesandthedefaultvaluesfornon-
persistent parameters are shown in “bold”inthecolumn
“Range”.
remote on;
DisconnectsHyperterminal.Thelocal/remotebuttonon
thefrontpanelisgreen.Hyperterminalcanreconnectto
the NBM-580 without pressing the front panel button�
remote off;
DisconnectsHyperterminal.Thelocal/remotebuttonturns
red.HyperterminalcannotreconnecttotheNBM-580until
thelocal/remotebuttonispressedandturnsgreen.
➩ Pressingthelocal/remotebuttonwhileitisgreenwill
disconnectwhateverisattachedtotheNBM-580(the
buttonwillashredandthenturngreen).
Welcomemessagewhenrstconnected:
“ConnectedtoNBM-580.Type“LIST_COMMANDS”forall
availableremotecmds.
Note:Allcommandsmustendinasemicolon.