Worth Data LZ404-RF Guide d'installation Page 72

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 73
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 71
72
Read Mode Settings Continued:
Add-on
Delay Timer
disable add-on wait more
default
,XA,
add-on wait mode = 0.25 seconds
,XB,
add-on wait mode = 0.50 seconds
,XC,
add-on wait mode = 0.75 seconds
,XD,
Since WPC-type codes (UPC, EAN) with add-on (supplements) have a high probability of unsuccessful
decoding, the scanner repeats decoding the add-on code during the specified period of time. It is effective to
read the add-on parts, but it will also cause a reduced response when a code without an add-on is read.
Margin Check
(Quiet Zone)
no margin check
.YN,
margin check 1/7 normal
,YO,
margin check 2/7 normal
,YP,
margin check 3/7 normal
,YQ,
margin check 4/7 normal
,YR,
margin check 5/7 normal
,YS,
margin check 6/7 normal
,YT,
margin check normal
default
,YU,
Power Saving
disable power saving (USB I/F default)
default
,XSC,
power saving after 0 seconds (RS-232 I/F default)
default
,E64,
power saving after 1 second
,XSH,
power saving after 2 seconds
,EB0,
power saving after 5 seconds
,EB1,
power saving after 10 seconds
,EB2,
power saving after 30 seconds
,XSD,
power saving after 10 minutes
,XSE,
power saving after 30 minutes
,XSF,
power saving after 60 minutes
,XSG,